Description
BX-FS048 IP65 explosion-proof twin-head emergency light combines two directional LED lamp heads, a robust metal enclosure and rechargeable battery backup in one compact industrial unit. Designed for fixed 220V emergency-lighting projects, it provides at least 1.5 hours of emergency operation and helps illuminate escape routes, equipment corridors and critical access points when normal power is interrupted.
Directional Emergency Lighting for Industrial Projects
Emergency lighting in factories and technical facilities must direct useful illumination toward the actual travel path. BX-FS048 uses two round LED heads that can be aimed in different directions, allowing one fixture to cover a doorway, corridor junction, stair approach or nearby operating area. The twin-head arrangement gives contractors greater flexibility than a single fixed beam while keeping installation concentrated around one battery enclosure.
The low, wide enclosure is manufactured with a bolted front cover and a side mounting structure suitable for permanent wall installation. Raised markings and panel geometry give the product a clear industrial appearance, while the metal lamp housings and protected cable connections match the demands of heavy-duty emergency-lighting projects. Its IP65 design helps resist dust and water ingress in appropriate industrial environments.
Twin Adjustable Heads
Two directional round LED heads can be aimed to illuminate separate sections of an emergency egress route.
IP65 Construction
A sealed metal enclosure supports use in dusty, damp and demanding industrial project environments.
Battery Backup
The built-in 1.2V Ni-Cd battery provides at least 1.5 hours of lighting after mains power failure.
Compact 3W System
Low rated power supports efficient emergency illumination for multi-unit industrial projects.

For effective project use, both lamp heads should be aimed during installation and verified under a simulated power failure. Routine inspection should include checking enclosure fasteners, cable entries, lens cleanliness, charging indication and emergency runtime. Maintenance intervals must follow the facility safety plan and applicable local rules. This practical commissioning process helps buyers obtain useful path illumination instead of relying only on the fixture’s rated specification.
Reliable Backup During Power Interruption
During normal operation, the internal battery remains ready for emergency use. When the mains supply fails, the fixture provides backup illumination for a minimum of 1.5 hours. The two heads can be positioned during commissioning so their beams support the approved evacuation plan. This makes BX-FS048 suitable for locations where a single beam may leave a dark corner or where two nearby route directions need coverage.
The 220V input is intended for projects using this nominal electrical supply. A 1.2V Ni-Cd rechargeable battery provides the emergency energy source. Final installation should be performed by qualified personnel according to local electrical and life-safety requirements, including the correct wiring method, mounting surface and scheduled battery testing.
Technical Specifications
| Model | BX-FS048 |
|---|---|
| Product Type | Explosion-Proof Twin-Head Emergency Light |
| Ingress Protection | IP65 |
| Rated Power | 3W |
| Input Voltage | 220V AC |
| Battery | 1.2V Ni-Cd rechargeable battery |
| Emergency Duration | ≥ 1.5 hours |
| Dimensions | 250 × 43 × 240 mm |
Industrial Applications
BX-FS048 can be considered for factories, industrial warehouses, maintenance workshops, utility rooms, service corridors, equipment areas, wastewater facilities and other controlled industrial spaces that require directional backup lighting. Its two-head format is particularly useful near corridor intersections, emergency doors, stair access points and areas where the approved layout calls for illumination in more than one direction.
Hazardous-location classifications and explosion-protection approvals vary by country, installation zone and project specification. Although the product enclosure carries industrial explosion-protection markings and the catalog identifies IP65 protection, buyers should confirm the required documentation before ordering. No ATEX, IECEx, UL or other regional approval is implied unless it is specifically listed in the quotation and verified by supporting documents.
B2B Project and OEM Support
Best Emergency Light supplies emergency-lighting distributors, electrical wholesalers, contractors, importers and project procurement teams. We support sample evaluation, quantity quotations, production planning, packaging discussions and repeat-order supply. Depending on project volume, buyers can discuss labels, manuals, cartons and other market-specific presentation requirements.
For a precise quotation, send us your destination market, required quantity, installation environment, delivery schedule and mandatory testing or certification documents. Our team will confirm the available configuration and sample details before bulk production.
Request a BX-FS048 Project Quote
Contact us with your project quantity and technical requirements for configuration confirmation, sample options, lead-time information and a competitive B2B quotation.