Description
Reliable Exit Guidance for Demanding Commercial Areas
The BX-B015 waterproof hanging LED exit sign is a self-contained emergency guidance luminaire designed for commercial and industrial escape routes. Its robust white housing supports a highly visible green running-man panel with a downward directional arrow, helping occupants identify the correct exit route when normal lighting is unavailable. A 3W LED light source, wide 85-265V AC input, integrated 3.7V 1500mAh rechargeable battery and three-hour emergency duration make it a practical choice for distributors, contractors and project buyers.
Key Product Advantages
Waterproof Housing
The enclosed housing is intended for demanding indoor locations where moisture, dust or cleaning conditions require a more protected exit-sign design.
Three-Hour Battery Backup
The integrated rechargeable battery supports three hours of emergency operation after a loss of normal mains power.
Wide Voltage Compatibility
An 85-265V AC input range supports international projects and helps distributors simplify multi-market inventory.
Clear Downward Direction
The bright green running-man pictogram and downward arrow provide fast visual guidance above doors and changes in escape-route level.
Built for Commercial Escape Routes
Exit signs must remain recognizable when occupants are unfamiliar with a building, visibility is reduced or the normal electrical supply has failed. The BX-B015 uses an internationally understood running-man symbol and a bold downward arrow to provide immediate directional information without relying on language. This makes the product suitable for hotels, warehouses, shopping centres, apartment buildings, factories, schools, hospitals, underground parking areas and transportation facilities.
The hanging format positions the sign below the mounting surface, improving visibility along corridors and across larger spaces. It can be installed above a final exit door, at a route transition or where the downward arrow is appropriate to the approved evacuation plan. The white top housing has a neutral appearance that integrates with a broad range of commercial interiors, while the green panel remains visually prominent. Final arrow direction, panel design, mounting position and viewing distance should always follow the project drawings and local safety requirements.

Electrical Performance and Emergency Operation
The 3W LED system provides energy-efficient sign illumination during normal operation and emergency conditions. When the mains supply is present, the internal charging circuit maintains the rechargeable battery. If normal power is interrupted, the emergency circuit uses stored battery energy to keep the sign visible for up to three hours. This duration is widely requested in commercial emergency-lighting projects and gives building occupants and safety teams additional time to respond to an outage.
The 3.7V 1500mAh rechargeable battery is contained within the luminaire, avoiding the need for a separate external battery box. Wide 85-265V AC input compatibility helps electrical contractors and importers specify one model across projects with different nominal supply voltages. Before ordering, buyers should confirm the required operating mode, charging specification, test function and market-specific electrical configuration against the approved sample and final technical agreement.
Installation and Maintenance Planning
Installers should mount the unit to a structurally sound surface using hardware suitable for the substrate and project environment. The sign panel should remain level, unobstructed and clearly visible from the intended approach direction. Supply wiring must follow the approved wiring diagram, local electrical rules and emergency-lighting circuit design. During commissioning, verify normal illumination, charging status and automatic transfer to battery operation by isolating the normal power supply under controlled conditions.
Facility teams should include the BX-B015 in the building emergency-lighting register. Routine visual checks can identify dirt, impact damage, loose fixings or an obstructed viewing path. Functional and duration tests should be completed at the intervals required by the local maintenance programme. If the battery no longer supports the specified duration, replace it only with an approved compatible type. Recorded inspection results help contractors and building owners plan maintenance, replacement stock and multi-site asset management.
Technical Specifications
| Model | BX-B015 |
|---|---|
| Product Type | Waterproof Hanging LED Exit Sign |
| Rated Power | 3W |
| Input Voltage | 85-265V AC |
| Battery | 3.7V / 1500mAh rechargeable battery |
| Emergency Duration | 3 hours |
| Dimensions | 355 x 110 x 210 mm |
| Installation | Hanging / surface mounted housing |
OEM and Project Supply
We welcome enquiries from emergency-lighting distributors, electrical wholesalers, contractors, engineering companies and importers. Project support may include samples, private-label branding, neutral or customised packaging, instruction materials and technical documentation according to order requirements. Please provide the destination market, estimated quantity, required pictogram or arrow direction, packaging preference and target delivery schedule so that we can prepare a focused quotation.
For bulk orders, all electrical details, markings, compliance documents, packaging and performance requirements should be confirmed through the final specification and approved sample before production. This helps maintain consistent quality across repeat deliveries and allows the product to fit more smoothly into the buyer’s existing emergency-lighting range.
Request a BX-B015 Project Quote
Contact us for samples, bulk pricing, OEM options, technical information and production lead times. Share your project type and required quantity for a tailored proposal.





Reviews