BX-B001 Vietnamese English LED Emergency Exit Sign with Right Arrow

  1. Vietnamese and English wording for multilingual commercial buildings.
  2. Running-man pictogram and right arrow for clear route direction.
  3. AC85-265V wide input with more than 1.5 hours of emergency operation.
  4. Slim 3W black housing for distributors, contractors and OEM projects.
SKU: BX-B001 Category:

Description

Vietnamese English LED emergency exit sign BX-B001 provides clear bilingual route identification for commercial projects serving Vietnam and other export markets. Its slim black face presents the words “LỐI THOÁT” and “EXIT” together with a running-man doorway pictogram and a large right-pointing arrow. Rated at 3W with AC85-265V input, a 1.2V 600mAh battery and more than 1.5 hours of emergency operation, this compact sign is designed for distributors, contractors and OEM buyers requiring a multilingual egress solution.

Key Advantages for Export and Commercial Projects

01

Bilingual Exit Message

Vietnamese “LỐI THOÁT” and English “EXIT” support clearer identification in multilingual buildings.

02

Right-Arrow Direction

A large arrow and running-man pictogram communicate the intended escape direction at a glance.

03

Wide AC Input

AC85-265V operation provides useful flexibility for projects across different regional power systems.

04

Slim Black Housing

The compact black-and-white design offers high visual contrast without a bulky cabinet.

BX-B001 Vietnamese English LED emergency exit sign installed in a commercial corridor
Bilingual right-direction exit identification for Vietnamese commercial and hospitality projects.

Clear Multilingual Route Identification

BX-B001 combines text and an internationally recognizable running-man graphic on one high-contrast panel. The Vietnamese and English wording helps occupants identify the sign’s purpose, while the doorway pictogram and right arrow communicate the route even when a viewer does not read either language fluently. This makes the model relevant to hotels, offices, factories, retail buildings and transportation facilities with local staff, international visitors or mixed-language workforces.

The long, low-profile enclosure measures 330 x 23 x 145 mm. Black vertical end caps frame the sign face, while narrow light-colored rails run along the top and bottom. The format is practical for placement above doors, at corridor junctions and near route changes where the approved evacuation plan directs occupants to the right. Final positioning, arrow direction and viewing distance should always be checked against the project drawings and applicable local safety requirements.

Technical Specifications

Specification BX-B001
Product Type Multilingual LED emergency exit sign
Rated Power 3W
Input Voltage AC85-265V
Battery 1.2V 600mAh
Emergency Duration More than 1.5 hours
Dimensions 330 x 23 x 145 mm

Typical B2B Applications

This bilingual emergency exit sign can be evaluated for hotels, serviced apartments, office buildings, schools, hospitals, factories, warehouses, shopping centers and public facilities in Vietnam. It is also relevant to international contractors and distributors supplying projects where Vietnamese and English identification is requested. The simple rectangular format works in both new construction and replacement programs, subject to mounting and electrical compatibility.

Legend, Direction and OEM Confirmation

Exit signage is directional, so artwork must be treated as a functional specification rather than decoration. Before ordering, confirm the exact spelling, accents, pictogram style, arrow direction, viewing side and mounting orientation. If left-arrow, double-sided or alternative-language versions are needed, provide an approved artwork file and project schedule for feasibility review. Custom legends, packaging, labels and documentation may be discussed according to quantity and technical requirements.

A pre-production sample is recommended before bulk purchasing. The sample lets the buyer verify text accuracy, illuminated appearance, contrast, dimensions, housing finish, wiring access, charging behavior and emergency runtime. For tender work, the signed-off sample and written specification can then be used as a reference during production inspection and site acceptance.

Installation, Testing and Maintenance

Qualified personnel should mount the sign securely in the location shown on the approved egress plan. Electrical connections must suit the local supply and remain protected inside the installation. After commissioning, simulate a mains failure to confirm automatic emergency operation and check that the bilingual legend and right arrow remain clearly visible from the intended approach.

Building operators should include the sign in routine emergency-lighting inspections. Check the enclosure, fixings, sign face, charging condition and battery-supported duration, and record results according to the facility’s safety procedure. Battery age, ambient temperature and maintenance history can influence backup performance. Certifications, environmental ratings and local compliance documents should be requested and verified for the ordered version rather than assumed from the catalog image.

Planning for Bulk Supply

For multi-floor buildings or phased construction, purchasers can organize deliveries by area and include spare units for maintenance after handover. To reduce site errors, each purchase order should identify the arrow direction and artwork revision. Confirm carton marks, accessories, inspection criteria and delivery timing before mass production. This gives importers, contractors and facility suppliers a clearer path from sample approval to repeat ordering.

Information to Include with Your Enquiry

To receive an accurate quotation, send the required quantity, installation country, supply voltage, legend language, arrow direction, mounting position and target delivery date. If the project has an approved signage schedule, share the relevant legend drawing or clear specification page. Buyers should also state whether they need samples, spare batteries, neutral packaging or custom carton marks. Complete information at the enquiry stage helps the supplier review feasibility, avoid artwork misunderstandings and prepare a more reliable production and delivery plan.

Request a Sample or Project Quote

Send Best Emergency Light your language, arrow direction, quantity and destination country. We can review the BX-B001 configuration and prepare a B2B quotation.